Si eres listo como un lince, comprarás en nuestra tienda My Account  Cart Contents  Checkout  
  Top » Catalog » -Measuring Equipment » My Account  |  Cart Contents  |  Checkout   
Categories
Green laser (532nm) (25)
Red laser (630nm) (13)
Violet laser (405nm) (12)
-Yellow Laser - (593nm) (3)
Infrared laser (808-980nm) (17)
-Laser Glasses- (15)
-Electroluminescent Lighting (20)
-Eyewear for IPL intense pulsed  (6)
-Ozone systems (4)
-Laser and optical sight - (8)
-Measuring Equipment (26)
-Sight- (9)
-Special-Lanterns (21)
batteries (28)
Electronics (41)
-Night Vision Goggles- (2)
Stands & Mounts (20)
Laser modules for disco (25)
laser module for lab (60)
Quick Find
 
Use keywords to find the product you are looking for.
Advanced Search
Information
Shipping & Returns
Privacy Notice
About us
Frequently Asked Questions


Fisher Dualscope FMP40 Coating Thickness Gauge 950,00€ 700,00€

Fisher Dualscope FMP40 Coating Thickness Gauge

Brand: "Fisher"
Model: "Dualscope FMP40"
for Functions:
Measurements on steel and iron, as well as on non-ferromagnetic metals and non-conductive substrates
Measurement of duplex coatings (lacquer / zinc) on steel with separate display of lacquer and zinc coatings
Measurement of the depth of the surface profile with the FPR1 probe
Includes in Meter and 2 probes. Manuals and software can be downloaded from the manufacturer's website: "Helmut-fischer"
Features
Interchangeable probes provide flexibility for a wide range of measurement tasks
Automatic probe and substrate material recognition
Measurement results are always visible via the large, easy-to-read color display
Simple device operation via intuitive menu
Acquisition of the measurement as soon as the probe is used
Adaptation to the measured part through zero point correction (normalization)
Simple corrective calibration
Fast data transfer via USB interface
Keypad lock prevents inadvertent operation
Variety of display languages ​​
Switch between "µm" and "mils" units of measure
Measurement with Tracking Screen for Continuous Surface Sampling
Visualization of important characteristics such as mean value, standard deviation, min, max and range
External start button: ideal for measurements on p. ex. hollow cylinders with small diameters
Acoustic and visual warning when tolerance limits are exceeded
Graphic evaluation of measurement results
Statistics of the most important characteristics shown in block and final results, as well as analysis of variance (ANOVA) values ​​
Instead of memory for 1 measurement task, application memory for up to 100 measurement tasks including calibration
Memory for up to 20,000 measured values ​​
Structuring of measured values ​​in up to 4000 blocks
Special measurement modes allowing coating thickness to be measured according to IMO PSPC, SSPC-PA2, QUALANOD or QUALICOAT
With USB interface

This product was added to our catalog on Wednesday 05 May, 2021.
Reviews
Phone number:
+0034665019380

Contact e-mail:
info@laserlince.com
Shopping Cart more
1 x Mount laser pointers view or Picatinny rail-20mm (H)
1 x Steel mounting bracket for attaching double-laser pointers
1 x Mounts sights or laser pointers 11mm Picatinny Rail (30mm)
1 x Compact aluminum mounting MP5 and G3 Picatinny 20mm rail
1 x picatinny rail mount for bow
1 x Aluminum mount M4 and M16 with 20mm Picatinny Rail
1 x Mount clamp to Picatinny rail with 25mm bracket
1 x Air oxygen analyzer (% O2), 8821 CNEX
1 x ACL4 Power regulator for RGB laser modules (TTL Controller)
1 x Carbon Monoxide Meter CO AS8700A
1 x A2 Module red laser line generator industrial focus 10mW (650nm)
1 x ECO5F radioactivity, nitrates and conductivity meter
1 x Microwave radiation meter DT-2G
1 x Goggles for green laser Eagle Pair
1 x Integral laser protection glasses 190-470 & 800-1700 OD5 +
1 x Ozone concentration analyzer in air 03
1 x 04 Red laser pointer 500mW (650nm)
1 x A4 Steel-aluminum bracket for 12mm industrial laser calibration
1 x Gafas metálicas opacas de protección láser e IPL para pacientes
1 x AGV 5mW 650nm red laser pointer with a fiber optic coupler
1 x Fisher Dualscope FMP40 Coating Thickness Gauge
1 x AGV 10mW 650nm red laser pointer with a fiber optic coupler
1 x 02 100mW red laser pointer (650nm) 2XAAA with security keys
1 x A8b 200mW Red Laser Module (650nm)
1 x Red and Infrared laser protection goggles 600 to 1100nm OD 6 +
1 x Linterna UltraFire de luz ultravioleta (3W de potencia)
1 x Wood Moisture% Meter 0-99.9%
1 x Laser protection glasses ultravioletade 190 to 400nm OD 5 +
1 x 08 Kaleidoscope red laser pointer 50mW (650nm) in two 1
1 x Infrared Spotlight 850nm 5W LED with ambient lighting sensor
1 x ARDUINO NANO REV3 ATmega328P board
1 x AG3 3000mW RGB laser module with TTL modulation
1 x MaxPower CREE Flashlight ML360 Special CR123A
1 x Electromagnetic Field Meter Impulse SOEKS 3D
1 x 40 Dupont Wire Cable 180mm length 2.54 mm male female
1 x Adjustable LXGD CR123A 5mW red laser for precision shooting
1 x Dual channel converter 110V-220V, 220V-110V
1 x 40 Dupont Wire Cable 2.54mm 180mm length male male
1 x White Light Flashlight TrustFire TR-1200 CREE emitters 5, 1200 l
1 x PH / Chlorine meter dissolved in water for swimming pools, aquar
1 x Flashlight UltraFire of white light (Philips Luxeon K2 emitter)
1 x Laser Power Meter 0.1mW to 2W , 200nm-20um Range
1 x Module with Humidity Sensor or Hygrometer for Arduino
1 x 07 Red laser collimator for 650nm Newtonian telescope
1 x 40W CO2 laser module Infrared 10600nm
1 x Digital air quality analyzer: 8 in 1
1 x Goggles CO2 infrared laser 10600nm OD 5+
1 x Red Laser Line Generators 5mW (650nm)
1 x Goggles for red laser Eagle Pair OD 5+
5745,00€
Notifications more
NotificationsNotify me of updates to Fisher Dualscope FMP40 Coating Thickness Gauge
Reviews more
Write ReviewWrite a review on this product!
Languages
Español English
Currencies

21 % de IVA incluido en todos los precios
Laserlince, S.L. / N.I.F.: B 47 635 859 / Registro Mercantil de Valladolid Tomo 1342 hoja VA-217 Inscrip.:1ª libro 0 folio 125.
Copyright 2008 © 2024 LASERLINCE